Start with material identity, not the percentage
Madecassoside is a defined Centella triterpene glycoside. TECA is used for a titrated, multi-component Centella triterpene system. “Centella total glycosides” also describes a component group rather than one molecule, while a general Centella extract can cover a much wider range of extraction and standardization profiles.
A label such as “95%” is therefore incomplete unless the specification states what is being measured and how the result is calculated.
Decision table for procurement and R&D
| Review point | Madecassoside | TECA | General Centella extract |
|---|---|---|---|
| Material type | Defined constituent or a specified isomer-based commercial grade | Standardized multi-component triterpene system | Botanical extract with supplier-specific composition |
| Assay question | Single Madecassoside peak or named isomer peaks combined? | Which glycoside and acid components are reported, and how is the total defined? | Which marker compounds, extract ratio or native-extract basis is used? |
| Evidence to match | Specification, method definition, chromatogram and batch COA | Component ranges, HPLC method, chromatogram and batch COA | Species, plant part, solvent, carrier, markers and contaminant controls |
How PINHONBIO® explains its standard Madecassoside 95 grade
For the standard commercial grade currently under review, the assay basis combines the specified HPLC peak-area percentages for Madecassoside and Asiaticoside B. A single-peak Madecassoside grade is a separate requirement and should be requested and quoted separately.
The example below explains the calculation basis only. It is not a Certificate of Analysis and must not be used as a future batch result.
| Illustrative HPLC peak | Retention time | Peak area | Included in combined-isomer assay |
|---|---|---|---|
| Asiaticoside B | 12.238 min | 8.95% | Yes |
| Madecassoside | 15.953 min | 86.24% | Yes |
| Asiaticoside | 30.467 min | 4.81% | No |
| Combined-isomer assay | 95.19% | Explanatory calculation | |
Retention time (min) · schematic rendering of the supplied batch chromatogram, not a replacement for the original analytical report.
What the buyer should request
- Exact product name, code, INCI or chemical identity and offered grade.
- A written assay definition identifying every peak or component included in the result.
- The current specification and analytical method, plus a traceable chromatogram where required.
- A batch-specific COA that uses the same names, limits, units and calculation basis.
- Product-specific formulation and stability information rather than parameters copied from another Centella material.
Sources used for this guide
- PubChem: Madecassoside
- European Medicines Agency: Centella asiatica assessment report
- PINHONBIO® internal Madecassoside assay-definition confirmation and supplied HPLC report; reviewed 14 August 2026.